file:
Year:
2 011
Publisher:
JACoW
Abstract:
This paper describes beam diagnostics at VEPP-2000 collider, based on visible synchrotron light analysis. These beam instruments include: SR beamline and optics; acquisition tools and high resolution CCD cameras distributed around the storage ring to measure the transverse beam profile and its position in vacuum chamber; photomultiplier tubes (PMT) which enables beam current measurements. Some applications of these measurement systems and their measurement results are presented.
- Log in to post comments