Beam Measurements with Visible Synchrotron Light at VEPP-2000 Collider

file: 
Year: 
2 011
Authors: 
Yu. A. Rogovsky, D.E. Berkaev, I. Koop, A.N. Kyrpotin, I. Nesterenko, A.L. Romanov, Y.M. Shatunov, D.B. Shwartz
Publisher: 
JACoW
Abstract: 
This paper describes beam diagnostics at VEPP-2000 collider, based on visible synchrotron light analysis. These beam instruments include: SR beamline and optics; acquisition tools and high resolution CCD cameras distributed around the storage ring to measure the transverse beam profile and its position in vacuum chamber; photomultiplier tubes (PMT) which enables beam current measurements. Some applications of these measurement systems and their measurement results are presented.